Oatey® Sure-Vent® 160 Branch, 72 Stack DFU Air Admittance Valves
Key Features & Benefits
- Sure-Vent® air admittance valve with ABS Sch. 40 adapter
- Opens and closes as needed by building's plumbing system
- Protective sleeve provides grip for installation and keeps valve free from debris
- 100% functionally tested at 1/4 in. H2O and 30 in. H2O, ensuring trouble-free performance
- Complies to ASSE Standard 1050 and 1051
- International Plumbing Code (IPC) and Uniform Plumbing Code (UPC) approved
- For warranty product details, refer to the Oatey Limited Warranty document
- Use as an alternative to a secondary vent in a DWV system
- Vents up to 160 DFU Branch or 72 DFU Stack
- One size approved to handle 2 in.–3 in. vent pipe
Specifications
Material: | ABS |
---|---|
Adapter Material: | ABS |
Brand: | Oatey |
---|---|
Connection Size: | 2 in. |
DFU Rating: | 160 Branch, 72 Stack |
Color: | White |
Adapter Size: | 2 in. - 3 in. |
More Specifications
Available in 2 variations
Frequently Asked Questions
No. The Sure-Vents are not designed for exposure to Ultra Violet Rays.
Can the Sure-Vent be installed in the attic?
Yes, with exceptions. The attic has certain conditions that can affect the AAV performance which should be considered before choosing this as a location. The temperature ranges that the Sure-Vent will operate in are -40°F to 150°F, your attic can experience drastic temperature variations depending on how it is vented and your geographic location. Insulation fibers can get caught inside the diaphragm which will make it harder for the diaphragm to open, or achieve a good seal when it is in the closed position. The Sure-Vent should be installed a minimum of six inches above the finished height of your insulation, and the attic must have an access point to conduct scheduled maintenance.
How high above the fixture trap should the Sure-Vent be located?
A minimum of four inches above the horizontal branch drain (trap).